0 66 31 / 911 54-0

 sales@gass-transformatoren.de

RKT - Toroidal core isolating transformer

RKT - Ringkern - Sicherheitstransformator - Teilverguss

Type: RKT

Toroidal core transformers

single - phase safety isolating transformer (SEC up to 50V)
and single - phase isolating transformer (SEC more than 50V)
according to DIN/VDE 0551-EN 60742-IEC 742
open-type assembly, partially encapsulated
connection: (the length is about 200mm)
PRI:-voltage: 230V
SEC-voltage: look at the table
frequency: 50/60 Hz
insulation class: T40/B
small dimensions, little weight
very low magnetic leakage field, minimal hum
low voltage drop, high efficiency
easy to install due to a screw for central fixing
the transformers are also available with other voltages
corresponding to your wishes 

data sheet RKT - Ringkern - Sicherheitstransformator - Teilverguss

technical data

 

RKM - Ringkern - Sicherheitstransformator - offene Bauform

Type: RKM

Toroidal core transformers

single - phase safety isolating transformer (SEC up to 50V)
and single - phase isolating transformer (SEC more than 50V)
according to DIN/VDE 0551-EN 60742-IEC 742
open - type assembly-type of protection IP00
connection: (the length is about 200mm)
PRI - voltage: 230V
SEC - voltage: look at the table
frequency: 50/60 Hz
insulation class: T40/B
small dimensions, little weight
very low magnetic leakage field, minimal hum
low voltage drop, high efficiency
easy to install due to a metal disc, flexible insulating disc
and a screw for central  fixing(the installation accessories are
included in the prince)
the transformers are also available with other voltages
corresponding to your wishes

data sheet RKM - Ringkern - Sicherheitstransformator - offene Bauform

technical data

RKV - Ringkern - Sicherheitstransformator - Vollverguss

Type: RKV

Toroidal core transformers

Single - phase safety isolating transformer (SEC up to 50V)
and single - phase isolating transformer (SEC more than 50V)
according to DIN/VDE 0551-EN 60742-IEC 742
plastic enclosure, resin- encapsulated transformer
connection: (the length is about 200mm)
PRI - voltage: 230V
SEC - voltage: look at the table
frequency: 50/60 Hz
insulation class: T40/B
small dimensions, little weight
very low magnetic leakage field, minimal hum
low voltage drop, high efficiency
easy to install due to a screw for central fixing
the transformers are also available with other voltages
corresponding to your wishes

data sheet RKV - Ringkern - Sicherheitstransformator - Vollverguss

technical data