Type: ELT/ELTS
Single - phase - power - transformers
according to DIN/VDE 0532
separate windings
primary - and secondary
voltage look at the list
frequency: 50/60 Hz
insulation class: T40/B up to 5,0 kVA
insulation class: T40/F up to 6,3 kVA
type of protection: IP00
( suitable for installation up to IP23)
resin impregnated against rust
we can also deliver other voltage
Type: USTG
Single - phase - universal - control - transformers
suitable for the most customary supply voltage from 210 V up
to 520 V; readjustment without inserting wire jumpes
according to DIN/VDE 0550-IEC 204-EN60204-UL-CUL
separate windings
open - type for assembly – type of protection P00
suitable for installation up to IP23
the terminals are protected against accidental
contact according to VBG 4
safety earth connection
the fixing holes are easily accessible
impregnated against rust with resin
PRI - voltage: 210/230/250/360/380/400/
420/440/460/480/500/520 V
SEC - voltage: see table
frequency: 50/60 Hz
isolation class: T40/B (VDE) class 105 (UL-CUL)
the transformers are also available with other constructions
corresponding to your wishes
data sheet USTG - Einphasen - Universal - Steuertransformatoren
Type: ESIT
Single - phase safety isolating transformers
safety isolating transformer according to DIN/VDE 0551
portable enclosure with grips
type of protection IP44 (splash proof)
(up to 500VA plastic enclosure / from 630VA sheet-steel
enclosure)
protection class II ( totally insulated)
PRI - voltage: 230 V
SEC - voltage: 24 V or 42 V-CEE-sockets
frequency: 50/60 Hz
isolation class: T40/B
the transformers are also available with other
constructions corresponding to your wishes
Type: ETTM
Single - phase - isolating - transformers for medicine
single-phase-isolating-transformers for medical rooms,
according to DIN/VDE 0107
isolating transformer according to DIN/VDE 0551-EN60742
protection class I; safety earth connection
type of protection IP00
(suitable for installation up to IP23)
shielding winding between PRI- and SEC-winding
SEC - winding with centre tap to monitor insulation
built-in thermal cut-out (break-contact)
the terminals are protected against accidental contact
impregnated against rust by resin
PRI - voltage:230 V
SEC - voltage: 230 V
frequency: 50/60 Hz
isolation class: T40/F
impedance voltage: no – load current: inrush current: the transformers are also available with other
constructions corresponding to your wishes
Type: STTG
Single - phase control and isolating - transformers
construction according to DIN/VDE 0550-IEC 204/742
EN 60204/60742- UL-CUL
separate windings
open - type for assembly – type of protection IP00
suitable for installation up to IP23
the terminals are protected against accidental
contact according to VBG 4
safety earth connection
the fixing holes are easily accessible
impregnated against rust with resin
PRI-voltage: see table
+/-5% taps for the adaptation to the supply voltage
SEC - voltage: 230V
frequency: 50/60 Hz
isolations class: T40/B (VDE) / class 105 (UL(CUL)
the transformers are also available with other constructions
corresponding to your wishes
Type: STSG
Single - phase control and safety transformers
construction according to DIN/VDE 0550-IEC 204/742
EN 60204/60742- UL-CUL
separate windings
open - type for assembly – type of protection IP00
suitable for installation up to IP23
the terminals are protected against accidental
contact according to VBG 4
safety earth connection
the fixing holes are easily accessible
impregnated against rust with resin
PRI - voltage: see table
+/-5% taps for the adaptation to the supply voltage
SEC - voltage: 24V
frequency: 50/60 Hz
isolations class: T40/B (VDE) / class 105 (UL(CUL)
the transformers are also available with other constructions
corresponding to your wishes
data sheet STSG - Steuer - Sicherheits - Transformator UL - zugelassen
Type: ETTT
Single - phase - isolating - transformers
isolating - transformers according to DIN/VDE 0551
portable enclosure with grips
type of protection IP44 (splash proof)
(up to 500VA plastic enclosure / from 630VA sheet-steel
enclosure)
protection class II ( totally insulated)
PRI - voltage: 230 V
SEC - voltage: 230 V-shock proof socket
frequency: 50/60 Hz
isolation class: T40/B
the transformers are also available with other
constructions corresponding to your wishes
Type: ESIV - 30
Single - phase safety isolating transformers
Single - phase safety isolating transformer
construction according to DIN/VDE 0551
plastic enclosure; resin-encapsulated transformer
totally isolated, protection class II
faston connection 4,8 x 0,8
PRI - voltage: 230 V
SEC - voltage: see table
The secondary voltages 11,5V and 23V are especially
for the operation of halogen lamps
frequency: 50/60 Hz
isolations class: T40/B
the transformer are also available with other voltage and
different pin assignment corresponding to your wishes
Type: ETV
Single - phase main transformers
single - phase isolating transformers (SEC up to 50V)
single - phase isolating transformers (SEC more than 50V)
according to DIN/VDE 0551-EN60742-IEC742
excellent protection against moisture by means of a
plastic enclosure and resin-encapsulated transformer
protection class II (totally insulated)
the terminals are protected against accidental
contact according to VBG 4
compact version, the fixing holes are easily accessible
type of protection: enclosure = IP65
terminal = IP20
PRI - voltage: 230 V or 400 V
SEC - voltage: see table
frequency: 50/60 Hz
isolations class: T40/B
the transformer are also available with other voltage and
different pin assignment corresponding to your wishes
data sheet ETV - Einphasen - Netz - Transformator, vergossen